Product Name | 60W/48V Industrial DIN Rail Power Supply | 60W/24V Industrial DIN Rail Power Supply | 60W/12V Industrial DIN Rail Power Supply |
Model | DP60-48 | DP60-24 | DP60-12 |
Group of Output | 1 | 1 | 1 |
DC Voltage | 48V | 24V | 12V |
Default Output Voltage @25℃ | 48.00-48.2V (Vin: 220VAC / LOAD:0A) | DC24.00-24.20V (Vin: 220VAC / LOAD:0A) | DC12.00-12.20V (Vin: 220VAC / LOAD:0A) |
Output Rated Current | 1.25A | 2.5A | 5A |
Output Current Range | 0-1.25A | 0-2.5A | 0-5A |
Output Rated Power | 60W | 60W | 60W |
Total Peak Output Power | Up to 90W(Sustainable time 10S/220VAC) | Up to 90W(Sustainable time 10S/220VAC) | Up to 90W(Sustainable time 10S/220VAC) |
Peak Output Current | 1.5A( Sustainable time 10S/220VAC) | 3.75A( Sustainable time 10S/220VAC) | 7.5A( Sustainable time 10S/220VAC) |
Ripple noise | Peak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz) | Peak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz) | Peak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz) |
Output Regulation Range @25℃ | DC47~56V | DC22.5~28V | DC11.5~14.5V |
Stabilized Voltage Precision @-20~65℃ | ±1% (DC48.48V-47.52V) | ±1% | ±1% |
Line Regulation @-20~65℃ | ±0.5% (DC48.48V-47.52V), (@ 85-264Vac input, 100% load) | ±0.5% (@ 85-264Vac input, 100% load) | ±0.5% (@ 85-264Vac input, 100% load) |
Load Regulation @-20~65℃ | ±1% (48.48V-47.52V), (@ 85-264Vac input, 0-100% load) | ±1% (@ 85-264Vac input, 0-100% load) | ±1% (@ 85-264Vac input, 0-100% load) |
Temperature Coefficient | ±0.03%/℃, (0~50℃) | ±0.03%/℃, (0~50℃) | ±0.03%/℃, (0~50℃) |
Output Start Time @25℃ | < 1.5S @ nominal input (100% load ) | < 1.5S @ nominal input (100% load ) | < 1.5S @ nominal input (100% load ) |
Output Hold Time @25℃ | > 20ms @ 115Vac, > 125 ms @ 230Vac (100% load ) | > 20ms @ 115Vac, > 125 ms @ 230Vac (100% load ) | > 20ms @ 115Vac, > 125 ms @ 230Vac (100% load ) |
Voltage Overshoot @-20~65℃ | ≤5% | ≤5% | ≤5% |
Input Voltage Range | 90~264VAC | 90~264VAC | 90~264VAC |
Input Rated Voltage Range | 100~240VAC | 100~240VAC | 100~240VAC |
Frequency Range | 47Hz~63Hz | 47Hz~63Hz | 47Hz~63Hz |
Starting Voltage @-20~65℃ | 90Vac | 90Vac | 90Vac |
Efficiency @ 25℃ | > 85.0% @ 115Vac, > 89.0% @ 230Vac | > 85.0% @ 115Vac, > 89.0% @ 230Vac | > 85.0% @ 115Vac, > 89.0% @ 230Vac |
Input Current @25℃ | < 1.40A @ 115Vac, < 0.80A @ 230Vac | < 1.40A @ 115Vac, < 0.80A @ 230Vac | < 1.40A @ 115Vac, < 0.80A @ 230Vac |
Power Factor @25℃ | PF>0.6 (at full load) | PF>0.6 (at full load) | PF>0.6 (at full load) |
Over Power Protection | 78~97W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.) | 78~97W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.) | 78~97W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.) |
Over Voltage Protection | 57~70V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. | 30~36V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. | 15~17V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage. |
Over Current | 1.5~1.875A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.) | 3~3.75A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.) | 6~7.5A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.) |
Short Circuit Protection | It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit. | It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit. | It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit. |
Operation Temperature and Humidity | -40~70℃; 20%~95%RH | -40~70℃; 20%~95%RH | -40~70℃; 20%~95%RH |
Storage Temperature and Humidity | -40℃~85℃; 10%~95%RH non-condensing | -40℃~85℃; 10%~95%RH non-condensing | -40℃~85℃; 10%~95%RH non-condensing |
Libration | Frequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis | Frequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis | Frequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis |
Surge | Acceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis | Acceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis | Acceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis |
Altitude | 2000m | 2000m | 2000m |
Security Standard | GB4943/EN60950 ■Reference □Certification | GB4943/EN60950 ■Reference □Certification | GB4943/EN60950 ■Reference □Certification |
Dielectric Strength | Input—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min. | Input—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min. | Input—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min. |
Grounding Test | Test Condition: 32A/2min; Ground bond: <0.1 ohms. | Test Condition: 32A/2min; Ground bond: <0.1 ohms. | Test Condition: 32A/2min; Ground bond: <0.1 ohms. |
Leakage Current @25℃ | Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz) | Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz) | Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz) |
Insulation Resistance | Input—Output: 10M ohms; | Input—Output: 10M ohms; | Input—Output: 10M ohms; |
Conducted Interference | EN55022, EN55024, FCC PART 15 CLASS B | EN55022, EN55024, FCC PART 15 CLASS B | EN55022, EN55024, FCC PART 15 CLASS B |
Radiated Interference | EN55022, EN55024, FCC PART 15 CLASS B | EN55022, EN55024, FCC PART 15 CLASS B | EN55022, EN55024, FCC PART 15 CLASS B |
Harmaonic current | EN61000-3-2 CLASS D | EN61000-3-2 CLASS D | EN61000-3-2 CLASS D |
Conducted Emission | EN61000-4-6 Level3 | EN61000-4-6 Level3 | EN61000-4-6 Level3 |
Radiated Emission | EN61000-4-3 Leve3 criterion B | EN61000-4-3 Leve3 criterion B | EN61000-4-3 Leve3 criterion B |
Power Frequency Emission | EN61000-4-8 Level3 | EN61000-4-8 Level3 | EN61000-4-8 Level3 |
Electrostatic Emission | EN61000-4-2 Level4 criterion B | EN61000-4-2 Level4 criterion B | EN61000-4-2 Level4 criterion B |
EFT | EN61000-4-4 Level4 criterion B | EN61000-4-4 Level4 criterion B | EN61000-4-4 Level4 criterion B |
Surge | EN61000-4-5 Level4 criterion B | EN61000-4-5 Level4 criterion B | EN61000-4-5 Level4 criterion B |
Dip and Interruption | EN61000-4-11 | EN61000-4-11 | EN61000-4-11 |
Dimension/Weight | 100*94*40mm / 300g | 100*94*40mm / 300g | 100*94*40mm / 300g |